MultiLoc™ Humeral Nail. EXPERT™ Humeral Nailing System. Diameters Available. Short Nails - 8 mm & 9.5 mm; Long Nails - 7 m and 8.5 mm. 7, 9, 11 mm. Length Available. 160 mm (Short Nail);180-315 mm (Long Nails) 150 mm (Short Nail);190-320 mm (Long Nails) Radius of Curvature.

Inventory Control Form 3.5/4.5 MM VA LCP™ PERIPROSTHETIC PROXIMAL FEMUR PLATING SYSTEM 3.5 mm VA-Locking PPFx Greater Trochanter Ring Attachment Plates, LEFT, SSt 3.5 mm VA-Locking PPFx Greater Trochanter Ring Attachment Plates, RIGHT, SSt Size 02.221.101 SMALL 02.221.103 LARGE Size 02.221.100 SMALL 02.221.102 LARGE.

At the end of this video, you should be able to describe the steps for placing the RFN-Advanced Retrograde Femoral Nailing System. This content is intended for Health Care Professionals in the United States.Implant failure is a rare event but Synthes has recognised that when these nails do fail, they commonly tend to fail at the screw / blade hole. This can mean that subsequent extraction is difficult. To overcome this there is a thread internally in the nail (below the blade hole) where an instrument can be attached and the nail removed more easily.About This Product. The LCP™ Proximal Tibia Plates are indicated for fractures of the proximal tibia and treatment of nonunions, malunions, and osteopenic bone. They are available in the following options: 3.5 mm LCP Proximal Tibia Plate. 3.5 mm LCP Proximal Tibia Plate – Low Bend. 4.5 mm LCP Proximal Tibia Plate.The RFN-Advanced is a retrograde nailing system for distal femoral fractures, with a locking attachment washer for enhanced fixation. It is approved by AO Technical Commission …SE_793148 AD page 2 / 8 Instructions for Use TFNA, 9 mm, long Right Left Length (mm) Femoral Neck Angle 04.037.916S 04.037.917S 260 125° 04.037.918S 04.037.919S 280 125°

LCP™ Ulna Osteotomy System (2.7 mm) 02.111.900, 02.111.900S, 02.111.901... The LCP™ Ulna Osteotomy System is a comprehensive system of plates allowing for ulnar shortening osteotomies. The system provides a low profile, angular stable fixation with a choice of two cut styles: transverse (90°) and oblique (45°).When it comes to purchasing a pre-owned vehicle, Ford is a brand that often comes to mind. Known for their reliability, performance, and wide range of models, Ford offers an impres...Inventory Control Form Some devices in this form may not have been licensed in accordance with Canadian law and may not be for sale in Canada Please contact your sales consultant for items approved for sale in Canada. *2.4 mm Cortex Screws in lengths 42–60 mm are available in the 2.4/2.7 mm VA-LCP Forefoot/Midfoot Plating System.

Synthes guarantees the compatibil-ity of its different original implants and/or instruments. The product-specific instructions for use as described by Synthes must be followed. It is not advisable to mix Synthes products with those of different manufacturers, since designs, materials, mechanics, and construction are not harmonized.

The DePuy Synthes physician locator service lists local practitioners who treat specific medical conditions with DePuy Synthes products. If you would like to be listed in the locator, simply fill out the form and submit this form to your DePuy Synthes sales consultant. Upon submission, your profile information may be viewed by potential patients.The Angular Stable Locking System (ASLS) provides angular and axial stability for screws used in combination with an intramedullary nail in the fixation of fractures. Provides improved stiffness and decreased interfragmentary movement compared to conventional locking. 1-3. Product Specifications. How to Use This Product.Large Fragment LCP® Instrument and ... - synthes.vo.llnwd.netProduct Specifications. How to Use This Product. About This Product. The TFN-ADVANCED Nailing System is a part of the Advanced Nailing System from DePuy …Synthes Tfna Inventory 7434-9176 Form Apply a synthes tfna inventory 8664 template to doing choose download workflow more streamlined. Get Form. Show details Hide details How information works. Open form follow the ... What produces the synthes rfna inventory legally binding? ...


Acp cricket enrollment form

Inventory Control Form Large Fragment LCP™ System Some devices in this form may not have been licensed in accordance with Canadian law and may not be for sale in Canada. Please contact your sales consultant for items approved for sale in Canada. LCPLARGEFRAGICF001v2 07/22 2 *Also available LengthLength 212.215212.201 42 …

INVENTORY CONTROL FORM Case Information (eg, Case ID): Synthes USA Products, LLC To order: (800) 523-0322 Synthes (Canada) Ltd. To order: (800) 668-1119 RIA 2 Reamer Irrigator Aspirator Date: Hospital: Surgeon: Procedure: Y N D Some devices in this form may not have been licensed in accordance with Canadian law and may not be for sale in Canada..

The Large External Fixation System uses a modular construction to allow flexibility and a variety of forms of assembly to externally stabilize long bones, pelvic ring fractures, arthrodesis, and osteotomies. The system combines the Modular Knee Bridge and the Pelvic Frame. Product Specifications.The U.S. Division of Trading and Markets defines current assets as the resources that are reasonably expected to be sold for cash or other receivables within one calendar year. If ...The Angular Stable Locking System (ASLS) provides angular and axial stability for screws used in combination with an intramedullary nail in the fixation of fractures. Provides improved stiffness and decreased interfragmentary movement compared to conventional locking. 1-3. Product Specifications. How to Use This Product.Variable Angle LCP™ Elbow System. Product Codes: 02.107.002, 02.107.002S, 02.107.102... View More. PRODUCT CODES. DESCRIPTION. The Variable Angle LCP™ Elbow System utilizes the variable angle locking technology platform that is based on a common approach to implant design and instrumentation, reducing complexity and ensuring a familiar ...At the end of this video, you should be able to describe the steps for placing the RFN-Advanced Retrograde Femoral Nailing System. This content is intended for Health Care Professionals in the United States.

4 DePuy Synthes Titanium Cannulated Tibial Nail Surgical Technique AO PRINCIPLES In 1958, the AO formulated four basic principles, which 1 4 2 3 4_Priciples_03.pdf 1 05.07.12 12:08 4 DePuy Synthes Expert Lateral Femoral Nail Surgical Technique AO PRINCIPLES In 1958, the AO formulated four basic principles, which3.5 mm VA LCP® Proximal Tibia Plate, Small Bend Available nonsterile or sterile-packed. Add “S” to catalog number to order sterile product. 02.127.210 4 holes, 87 mm, right 02.127.211 4 holes, 87 mm, left 02.127.220 6 holes, 117 mm, right 02.127.221 6 holes, 117 mm, left 02.127.230 8 holes, 147 mm, right 02.127.231 8 holes, 147 mm, left 02.127.240 …241.618, 241.619, 241.622... Our locking calcaneal plates are available in mini, short, long, and extra-long lengths, with both left and right designs available. They offer a fixed-angle construct and permit multiple fixation points to buttress small fragments. They accept standard 2.7 and 3.5 mm cortex screws and 3.5 mm locking screws.With Augmentation Option. Technique Guide Synthes 1. Open the catalog to page 3. PFNA. Proximal Femoral Nail PFNA Nail The anatomical design guarantees an optimal fit in the femur. The nail design has been well proven in over 450,000 cases performed with the PFN and PFNA.The Angular Stable Locking System (ASLS) provides angular and axial stability for screws used in combination with an intramedullary nail in the fixation of fractures. Provides improved stiffness and decreased interfragmentary movement compared to conventional locking. 1-3. Product Specifications. How to Use This Product.The RFN-Advanced is a retrograde nailing system for distal femoral fractures, with a locking attachment washer for enhanced fixation. It is approved by AO Technical Commission …The Large External Fixation System uses a modular construction to allow flexibility and a variety of forms of assembly to externally stabilize long bones, pelvic ring fractures, arthrodesis, and osteotomies. The system combines the Modular Knee Bridge and the Pelvic Frame. Product Specifications.

4. DePuy Synthes TF10816 RFNA MDR Indication Language. 07/03/2022. Windchill Document #0000317918 5. DePuy Synthes RFNA Nail Inlay Axial Pullout Design Verification Report. 08/20/2020. Windchill Document #0000293479 6. DePuy Synthes RFN-Advanced System Locking Attachment Washer Rationale. 09/30/2020. Windchill …

Completing Synthes Rafn Nail Inventory Steering Form 2020-2023 online with US Legal Forms. Easily fill out PDF blank, edit, and sign them. Save or instantly send your ready documents.DESIGN EVIDENCE Results of the testing are summarized below, and comparison of 200 the nailing systems are displayed in Figure 6. 100 100 Pre-Fatigue Post-Fatigue Pre-Fatigue • The TFNA Nail mean slippage load in the pre-conditioning test Nail TFNA was 15% and 92% greater than the INTERTAN Nail and Gamma3 Nail, respectively; the TFNA Nail mean slippage load in the post-conditioning test was ...Product Specifications. How to Use This Product. About This Product. The TFN-ADVANCED Nailing System is a part of the Advanced Nailing System from DePuy …The Universal Small Fragment System can support all 2.7 mm/3.5mm non-locking, LCP™ System, and VA LCP™ Locking Technologies. It consists of two components: A core set of instruments, screws, and standard implants. Modular anatomic implant trays for supported small fragment anatomy. Get in Touch with a Sales Consultant.Synthes (USA) Synthes (Canada) Ltd. To Order: (800) 523-0322 To Order: (800) 668-1119 Date: Hospital: Surgeon: Procedure: Implants P J3266-K 3/11 Inventory Control Form DHS/DCS & DHS/DCS One-Step Insertion plvllllpklgulpu. † NT NT 4 16 mm 212.106 20 mm 212.108 4 4.x NT NT 44 4 4 16 mm 4 18 mm 4 20 mm 4 22 mm 44 4 4mm 4 28 mm 4 30 mm 4 32 mm ...SE_793147 AC page 2 / 6 Instructions for Use Femoral Recon Nail, Greater Trochanter B 9 mm Right Left Length 04.033.958S 04.033.959S 280 04.033.960S 04.033.961S 300Inventory Control Form Variable Angle Locking Hand System Titanium 1.3 mm Titanium Locking Plates* 04.130.150 Straight Plate, 6 holes 04.130.151 Straight Plate, 12 holes 04.130.152 T-Plate, 3 holes head, 5 holes shaft 04.130.153 Y-Plate, 3 holes head, 5 holes shaft 04.130.154 Phalangeal Base Plate, 2 holes head, 5 holes shaftCompleting Synthes Rafn Arrest Inventory Control Form 2020-2024 online with US Legal Download. Easily fill out PDF blank, edit, and sign them. Saving or ... Tips on how to fill out, edit and sign Synthes rfna physical control web …


Sanrio store honolulu

Some advantages of inventory management include ensuring that a business does not spend money on unnecessary product orders and tracking which products are selling and which are no...

When it comes to managing your stock inventory, having an efficient and accurate system in place is crucial. One popular option that many businesses turn to is using an Excel-based...Synthes (USA) 1690 Russell Road Paoli, Pennsylvania 19301 Re: K042986 Trade/Device Name: Synthes (USA) Low Profile Neuro System Regulation Number: 21 CFR 882.5250 Regulation Name: Burr hole cover Regulatory Class: 1I Product Code: GXR, HRS Dated: October 28, 2004 Received: October 29), 2004 Dear Ms. Boyle:SE_793149 AA page 2 / 5 Instructions for Use Retrograde Femoral Nail Advanced Devices in scope Retrograde Femoral Nail Advanced, 5 Degree Bend LengthInventory Control Form Small Fragment Locking Compression Plate (LCP™) System 204.848 3.5 mm Locking Screws, self-tapping, with StarDrive™ Recess Length 202.830 30 mm 202.832202.812 32 mm 202.834 34 mm 202.816 202.836 36 mm 202.818 202.838 38 mm 202.840202.820 40 mm 202.845 45 mm 202.850 50 mm 202.826 202.855 55 mm Length 212.113 34 mm 212. ...synthes.vo.llnwd.netInventory Control Form 4.5 mm VA LCPTM Curved Condylar Plate System Some devices in this form may not have been licensed in accordance with Canadian law and may not be for sale in Canada. Please contact your sales consultant for items approved for sale in Canada. SS/VALCPCC/ICF/V2 04/22 Page 1 of 2 To order (USA): 800-523-0322This site is published by the DePuy Synthes Companies, which are solely responsible for its content. This site is intended for use by residents of Latin America, Europe, Middle East and Africa, Asia & Pacific only.DESIGN EVIDENCE Results of the testing are summarized below, and comparison of 200 the nailing systems are displayed in Figure 6. 100 100 Pre-Fatigue Post-Fatigue Pre-Fatigue • The TFNA Nail mean slippage load in the pre-conditioning test Nail TFNA was 15% and 92% greater than the INTERTAN Nail and Gamma3 Nail, respectively; the TFNA Nail mean slippage load in the post-conditioning test was ...02.226.010, 02.226.011, 02.226.012... View More. PRODUCT CODES. DESCRIPTION. DePuy Synthes Headless Compression screws are available in a range of sizes from 1-5-6.5 mm. They are self-drilling and self-tapping, allowing surgeons to control compression during fixation procedures. Get in Touch with a Sales Consultant.About This Product. The Hindfoot Arthrodesis Nail permits a proper hindfoot alignment due to features such as: · Distal and talar locking options. · A spiral blade. · Lateral bend · End caps for improved stability2,3. Get in Touch with a Sales Consultant.The EMAX™ 2 Plus System is the ultimate high-powered, lightweight 1,2, small bone cutting system. Designed for surgeon comfort, this lightweight 1,2 device gives surgeons the flexibility 1,3,7, power, and low noise they need for long, complex neurosurgery and spinal procedures. MIDAS REX MR7 High-Speed Drill System (Medtronic)The Angular Stable Locking System (ASLS) provides angular and axial stability for screws used in combination with an intramedullary nail in the fixation of fractures. Provides improved stiffness and decreased interfragmentary movement compared to conventional locking. 1-3. Product Specifications. How to Use This Product.

Inventory Control Form Small Fragment Locking Compression Plate (LCP™) System 204.848 3.5 mm Locking Screws, self-tapping, with StarDrive™ Recess Length 202.830 30 mm 202.832202.812 32 mm 202.834 34 mm 202.816 202.836 36 mm 202.818 202.838 38 mm 202.840202.820 40 mm 202.845 45 mm 202.850 50 mm 202.826 202.855 55 mm …Inventory Control Form TFN-ADVANCED™ Proximal Femoral Nailing System TFN-ADVANCEDTM System (TFNA), Long Nails, 11 mm distal diameter, sterile Right Part # Left Part # Length (mm) Femoral Neck Angle 04.037.120S 04.037.121S 300 125° 04.037.122S 04.037.123S 320 125° 04.037.124S 04.037.125S 340 125° 04.037.126S 04.037.127S …Running a restaurant comes with its fair share of challenges, and one of the most crucial aspects to manage efficiently is inventory. Proper restaurant inventory management can gre... cece___rose 6 DePuy Synthes Titanium Cannulated Lateral Entry Femoral Recon Nail Surgical Technique Clinical Cases Case 1–Standard locking • 85-year-old female • Isolated femoral shaft fracture (AO 32-A1.2) For simple shaft fractures, two proximal and two distal ML locking screws are normally sufficient to stabilize the fracture.Data hosted within SyntheticMass has been generated by Synthea TM, an open-source patient population simulation made available by The MITRE Corporation.. The data is free from cost, privacy, and security restrictions. unimas schedule chicago DESCRIPTION. The Femoral Neck System (FNS) is a solution for femoral neck fractures where the growth plates have fused or cannot be crossed. Designed for improved angular stability 1 and rotational stability 2 with the intent to reduce reoperations related to fixation complications. Product Specifications. How to Use This Product. weed taste in mouth The Angular Stable Locking System (ASLS) provides angular and axial stability for screws used in combination with an intramedullary nail in the fixation of fractures. Provides improved stiffness and decreased interfragmentary movement compared to conventional locking. 1-3. Product Specifications. How to Use This Product.Complete Synthes Rafn Bolt Inventory Control Form 2020-2023 get use US Legal Forms. Easily fill out PDF clear, edit, and sign them. Save or instantly send your ready documents. lvvv investorshub About This Product. The Hindfoot Arthrodesis Nail permits a proper hindfoot alignment due to features such as: · Distal and talar locking options. · A spiral blade. · Lateral bend · End caps for improved stability2,3. Get in Touch with a Sales Consultant. early 2000 nickelodeon shows Handy tips for filling out Synthes rfna inventory online. Printing and scanning is no longer the best way to manage documents. Go digital and save time with signNow, the best solution for electronic signatures.Use its powerful functionality with a simple-to-use intuitive interface to fill out Synthes tna inventory online, e-sign them, and quickly share them … georgia rut dates MultiLoc™ Humeral Nail. EXPERT™ Humeral Nailing System. Diameters Available. Short Nails - 8 mm & 9.5 mm; Long Nails - 7 m and 8.5 mm. 7, 9, 11 mm. Length Available. 160 mm (Short Nail);180-315 mm (Long Nails) 150 mm (Short Nail);190-320 mm (Long Nails) Radius of Curvature.TFN-ADVANCED™ Proximal Femoral Nailing System (TFNA) – Screw Only fi Surgical Technique 3 The AO Principles of Fracture Management 1. Müller ME, Allgöwer M, Schneider R, Willenegger H. Manual of Internal Fixation. 3rd ed. Berlin, Heidelberg New York: Springer 1991. volpe funeral home Synthes (USA) Synthes (Canada) Ltd. To Order: (800) 523-0322 To Order: (800) 668-1119 Date: Hospital: Surgeon: Procedure: Patient Information: Inventory Control Form 2.7 mm / 3.5 mm Variable Angle LCP Elbow System 02.107.002 2 holes, right 02.107.102 2 holes, left 2.7 mm / 3.5 mm Variable Angle LCP Proximal Olecranon Plates 02.107.202 2 holes ...Now that summer is over, it's a good time to log into your airline and hotel accounts. Check to see how many points or miles you have, when they expire and check for any leftover c...This site is published by the DePuy Synthes Companies, which are solely responsible for its content. This site is intended for use by residents of Latin America, Europe, Middle East and Africa, Asia & Pacific only. al bladez lawn care location Completing any kind of forms, including the synthes rfna inventory electronically seems like a pretty simple process at first glance. Nevertheless, taking into account the nature of digital files, different market-specific rules and compliances are often unintentionally overlooked or misinterpreted.Complete Synthes Rafn Nail Inventory Control Form 2020-2024 online is US Legal Form. Slight fill out PDF blank, edit, and print they. Save or instantly send your ready paper. We use ... How go filling and sign Synthes rfna inventory control How to … waring sullivan home at birchcrest Synthes products supplied in a non-sterile condition must be cleaned and steam-sterilized prior to surgical use. Prior to cleaning, remove all original packag - ing. Prior to steam-sterilization, place the product in an approved wrap or contain - er. Follow the cleaning and sterilization instruction given by the Synthes “Import-ant ...At the end of this video, you should be able to describe the steps for placing the RFN-Advanced Retrograde Femoral Nailing System. This content is intended for Health Care Professionals in the United States. elden ring rune arc farming DePuy Synthes, RFN-Advanced System Locking Attachment Washer Rationale. 09/30/2020. Windchill Document #0000302371 9. DePuy Synthes, RFNA Nail/LAW Static Construct Design Verification Report. 04/28/2020. Windchill Document #0000293480* 10. DePuy Synthes, FRN Functional Design Requirements and Verification-Validation … when do chapman decisions come out Trauma & Extremities. Our Trauma & Extremities portfolio offers comprehensive solutions for the treatment of fractures, deformities, and other orthopaedic traumas. Our wide range of surgical instruments and fixation products are designed to provide solutions tailored to the diverse needs of orthopaedic professionals and patients.02.226.010, 02.226.011, 02.226.012... View More. PRODUCT CODES. DESCRIPTION. DePuy Synthes Headless Compression screws are available in a range of sizes from 1-5-6.5 mm. They are self-drilling and self-tapping, allowing surgeons to control compression during fixation procedures. Get in Touch with a Sales Consultant.Inventory Control Form FRN-ADVANCED™ Piriformis Fossa Femoral Recon Nailing System Implants (continued) Available non sterile and sterile packed. Add “S” to catalog …