Synthes distal fibula inventory.

Part of the DePuy Synthes locking compression plate (LCP) System. Precontoured - Shaped to provide spring-effect, to aid in reduction - Dual hook configuration facilitates placement. Versatile - A single 3-hole plate can be used in multiple locations, applied to either the right or left side of the anatomy, resulting in less inventory ...

The Universal Small Fragment (USF) System is intended to be used for small bone trauma, including anatomy such as Shoulder, Clavicle, Elbow, Tibia and Fibula. The core set can support any DePuy Synthes 2.7mm or 3.5mm non-locking, LCP® or VA LCP® Implant System. Training topics for USF. System Trays. Instruments..

DESCRIPTION. LOT #. UDI. FibuLock Implant System, sterile. Actuation Driver Proximal Reamer, cannulated, 3.2 mm Distal Reamer, cannulated, 6.2 mm AR-8973DS Drill, 2 mm Guidewire, spade tip, 1.1 mm × 22 in Guidewire, 1.6 mm x 12 in End Cap. FibuLock Removal Kit, Sterile. AR-8973RK Removal Screw Strike Plate Deactivator.Anatomically Contoured Locking Plates with Compression. The Periarticular Locking Plate System aims to combine optimal fit with advanced locking technology to offer a system for the treatment of comminuted fractures or fractures where deficient bone stock or poor bone quality is a factor. Anatomy. Ankle.LCP Dia-Meta Volar Distal Radius Plates LCP Distal Fibula Plates LCP Distal Humerus Plates LCP Distal Radius System 2.4 LCP Distal Tibia Plate LCP Distal Ulna Plate LCP Extra-articular Distal Humerus Plate LCP Hook Plate 3.5 LCP Locking Compression Plate LCP Low Bend Medial Distal Tibia Plates 3.5 mm LCP Medial Proximal Tibial Plate 3.5The LCP Low Bend Medial Distal Tibia Plate 3.5 mm is part of the Synthes Small Fragment LCP system that merges locking screw technology with conventional plating techniques. The combi-holes in the LCP plate shaft combine a dynamic compression unit (DCU) hole with a locking screw hole. Combi-holes provide the flexibility of axial compression and ...DePuy Synthes application notes for LCP plates). 1. Position the patient Place the patient in the beach-chair position. Tilt the head away from the operated side, with care for the position of the neck. A sandbag under the thoracic spine allows the scapula to fall backwards: this aids realignment and re - duction of the fracture.

Locking screws serve to provide stability to comminuted, unstable me- taphyseal fractures or in osteopenic bone. The A.L.P.S. Fibula Plating System is intended for the fixa- tion of fractures, osteotomies and non-unions of the fibula, malleolus, distal tibia, metatarsals, scapula, clavicle, distal humerus and humeral head, olecranon, ulna ...We would like to show you a description here but the site won't allow us.1. DePuy Synthes 2.7mm VA LCP Clavicle Plates Surgical Technique Guide, 103752541 rev 2 01/21. 2. DePuy Synthes. Shape Verification Analyses. Windchill #0000290902, 0000295170, 0000290186, 0000290903, 2020. 3. Robinson CM. Fractures of the clavicle in the adult. Epidemiology and classification. J Bone Joint Surg Br. 1998;80:476-484. 4.

Both anatomic fibular plates and 1/3 tubular plates can be utilized per surgeon preference; however non-anatomic plates must be precontoured on the back table prior to insertion. The plate is then inserted into the incision, pushed proximally in order so that the distal aspect of the plate enters the incision and then is pushed distally.

Approach. stack of blue towels under anterior ankle to elevate limb. mark out lateral malleolus, anterior and posterior borders of fibula, borders of Achilles. place dry lap over marked incision. exsanguinate limb and inflate tourniquet. incision ~6-8cm in length along posterolateral border of fibula.Offset syndesmotic and lateral fibula plates allow for precise syndesmotic fixation. Versatile, low-profile plate designs are Type II anodized, pairing increased strength with minimal construct prominence. System features a wide range of plates including hook, medial & posterior tibia, 1/3 tubular and syndesmosis plates. Contact your sales rep.DePuy Synthes launched the FIBULINK® Syndesmosis Repair System in the U.S. to treat traumatic injuries to the syndesmosis. DePuy Synthes acquired the technology earlier this year from Akros Medical. FIBULINK is the first system to offer a short high-strength suture bridge, which eliminates the risk of complications associated with broken...2.7 MM VA LCP™ CLAVICLE System. Product Codes: 02.112.610, 02.112.611, 02.112.612... View More. PRODUCT CODES. DESCRIPTION. Designed based on an analysis of clavicle CT scans to enhance plate-to-bone fit on a broad range of patients 1 and to treat lateral, shaft and medial fractures for small, medium and large clavicles.


Fjordur dino spawn map

Opening the Distal Femur 1 Position Patient Position the patient supine on a radiolucent table. The knee of the injured leg should be fl exed 30° – 40°. A leg roll may be used to allow proper reduction and stabiliza-tion of the fracture. Position the image intensifi er to allow visualization of the proximal and distal femur in AP and ...

Purchase a discounted Synthes 02.112.110 LCP Posterolateral Distal Fibula Plate, Right from Alpha Biomedical with a 6 month warranty. Site Information. MAIN MENU. Home; Sell Your Surgical Instruments; ... Synthes 02.112.143 LCP Lateral Distal Fibula Plate, 6 Hole, Left . $225.00. Add To Cart. Join Our Mailing List for special offers! Name ....

Our LCP™ Distal Tibia Plates are part of the DePuy Synthes Locking Compression Plate (LCP) System that merges locking screw technology with conventional plating techniques. The stainless-steel plates feature Combi holes, allowing fixation with locking or cortex screws. Product Specifications. How to Use This Product.Inventory Control Form 2.7 mm/3.5 mm Variable Angle LCP Ankle Trauma System Available nonsterile or sterile-packed. Add “S” to catalog number to order sterile product. 2.7 mm / 3.5 mm Variable Angle LCP Medial Distal Tibia Plates 02.118.002 4 holes, right 02.118.003 4 holes, left 02.118.004 6 holes, right 02.118.005 6 holes, left2 DePuy Synthes 2.4 ®mm Variable Angle LCP Distal Radius System Surgical Technique. 2.4 MM VARIABLE ANGLE LCP DISTAL RADIUS SYSTEM. Plate features. Three head sizes accommodate . patient anatomy. • Narrow – 6-hole head (19.5 mm) • Standard – 6-hole head (22 mm) – 7-hole head (25.5 mm) • Anatomically contoured volar distalThe LCP Anterolateral Distal Tibia Plate 3.5 is indicated for: – Extra-articular and simple intra-articular distal tibia fractures – Distal tibia fracture, percutaneous or reducible by limited arthrotomy – Distal tibia fracture extending into the diaphyseal area Synthes 5 0x6.000.333_AB.qxp:0X6.000.333_AB 04.12.2008 14:57 Uhr Seite 5DESCRIPTION. The Titanium Cannulated Tibial Nail-Ex offers a variety of proximal and distal locking options for tibial fractures, allowing the surgeon to tailor fixation to the fracture pattern. The system has a universal design, allowing use on the left or right tibia. Product Specifications. How to Use This Product.Variable Angle Locking Patella Plating System. The VA Locking Anterior Patella Plate 2.7 is designed to address different fracture patterns as per approved indication. The surgical technique guide includes two sections: Complex Fractures - 3-hole and 6-hole plates are recommended. Simple Fractures - Core, 3-hole, and 6-hole plates may be ...

2.7 mm/3.5 mm LCP Lateral Distal Fibula Plates 2.7 mm VA LCP Lateral Distal Fibula Plates 10 One-Third Tubular Plates, With Collar Ordering Information 2.7 mm/3.5 mm LCP Posterolateral Distal Fibula Plates Stainless steel Titanium Holes Length (mm) 241.321 441.321 2 21 241.331 441.331 3 33 241.341 441.341 4 45 241.351 441.351 5 57 241.361 441. ...Quick steps to complete and e-sign Va ankle inventory online: Use Get Form or simply click on the template preview to open it in the editor. Start completing the fillable fields and carefully type in required information. Use the Cross or Check marks in the top toolbar to select your answers in the list boxes.LCP Distal Femur and LCP Proximal Lateral Tibia (LISS) Stainless Steel and Titanium. Synthes (USA) To Order: (800) 523-0322 Synthes (Canada) Ltd. To Order: (800) 668-1119.Conclusion: Cannulated intramedullary screw fixation can serve as a minimally invasive, safe, and satisfactory treatment for distal fibular fractures with resulting high union rates and low complication rates. Levels of Evidence: Level IV: Retrospective, case series. Keywords: cannulated intramedullary screw; distal fibular fracture; high-risk ...Gather AI, a startup using drones and software to sell inventory management services to warehouse operators, has raised $10 million. Gather AI, a startup using drones to inventory ...Minimally invasive plate osteosynthesis (MIPO) has been reported to be superior to open reduction and internal fixation (ORIF) in the treatment of different long bone fractures. Nevertheless, in distal fibula fractures, the evidence of MIPO remains scarce. The aim of this retrospective study was to compare the clinical and radiological outcomes of the minimally invasive techniques applied to ...Use the Torque Limiter 1.5 Nm (511.115) and the Screwdriver Shaft (Hex 314.030, Stardrive 314.116) for the motor-driven insertion of the locking screw. Stop the motor before locking, fix the torque limiter and the screw-driver shaft to the Handle with Quick Coupling (311.431) and tighten the screw. After one click, the optimal torque is reached.

LCP Distal Femur and LCP Proximal Lateral Tibia (LISS) Stainless Steel and Titanium. Synthes (USA) To Order: (800) 523-0322 Synthes (Canada) Ltd. To Order: (800) 668-1119.

The 2.0 mm LCP Distal Ulna Plate is indicated for fixation of fractures, osteotomies, nonunions, replantations, and fusions of small bones and small bone fragments, particularly in osteopenic bone. 4 DePuy Synthes 2.0 mm LCP® Distal Ulna Plate Surgical T. Clinical Examples Examples include: – Fractures of the ulnar head where the articular ...Pediatric LCP® Plate System Surgical Technique DePuy Synthes 5 Pediatric LCP Plates are available in the following sizes and angles.* Pediatric LCPPlates **Screws sold separately **Additionally available. Angle Recommended Use 2.7 mm Plates 3.5 mm and 5.0 mm Plates 90˚ (Condylar) Distal femur osteotomies and fractures 3, 5, or 7 holesBar inventory spreadsheets designed by our bar expert. Click through to find inventory templates for bars, wine bars, and restaurant bars. Retail | Templates WRITTEN BY: Mary King ...14 Synthes Large and Medium-Size External Fixators Surgical technique Approach to the femur A lateral approach to the femur within a 30° angle is recom-mended. A medial approach is also possible from a distal direc-tion. Approach to the pelvis There are two recommended options for pin placement of the external fixation assembly in the pelvis.Retailers replenish stock with automatic programs. Learn how inventory management systems work. Advertisement If you're standing in the middle of a big retailer such as Walmart, an...- The three locking holes distal to the plate head accept 3.5 mm locking screws with StarDrive Recess to secure plate position. The hole angles allow the locking screws to converge with three of the four locking screws in the plate head to support medial fragments. - Combi holes, distal to the three angled locking holes, combine aThe Acutrak 2 - 7.5 is available in sizes from 40 mm to 120 mm and is inserted using a 4.0 mm hex driver over a .094" guide wire. The Acutrak 2 - 5.5 is part of the latest evolution in fully-threaded headless screw fixation. With instrumentation designed to simplify the surgical technique, the Acutrak 2 - 5.5 is composed of 8 unique screw size ...


Gonzales funerals and cremations obituaries

Please consult the surgical technique guide "Philos and Philos long" (036.000.166) for detailed information on the implant and its indications. For optimal plate positioning, insert two positioning Kirschner wires 2 mm - 4 mm lateral to the bicipital groove and 5 mm - 7 mm below the tip of the greater tubercule.

2 DePuy Synthes 2.4 ®mm Variable Angle LCP Distal Radius System Surgical Technique. 2.4 MM VARIABLE ANGLE LCP DISTAL RADIUS SYSTEM. Plate features. Three head sizes accommodate . patient anatomy. • Narrow - 6-hole head (19.5 mm) • Standard - 6-hole head (22 mm) - 7-hole head (25.5 mm) • Anatomically contoured volar distalThe Femoral Recon Nail System is an integrated nailing system designed to adapt to multiple surgical approaches. The FRN System provides the choice of Greater Trochanter (GT) and Piriformis Fossa (PF) entry points and anatomical nail designs to support surgical preferences and facilitate hospital standardization. Contact Us.Purchase a discounted Synthes 02.112.110 LCP Posterolateral Distal Fibula Plate, Right from Alpha Biomedical with a 6 month warranty. Site Information. MAIN MENU. Home; Sell Your Surgical Instruments; ... Synthes 02.112.143 LCP Lateral Distal Fibula Plate, 6 Hole, Left . $225.00. Add To Cart. Join Our Mailing List for special offers! Name ...Position the C-arm for an AP view of the proximal femur. With long forceps, hold the ruler alongside the lateral thigh, parallel to and at the same level as the femur. Adjust the ruler until the proximal end is at the desired nail insertion depth. Mark the skin at the proximal end of the ruler.Variable Angle Locking Patella Plating System. The VA Locking Anterior Patella Plate 2.7 is designed to address different fracture patterns as per approved indication. The surgical technique guide includes two sections: Complex Fractures - 3-hole and 6-hole plates are recommended. Simple Fractures - Core, 3-hole, and 6-hole plates may be ...Inventory Control Form 3.5/4.5 MM VA LCP™ PERIPROSTHETIC PROXIMAL FEMUR PLATING SYSTEM 3.5 mm VA-Locking PPFx Greater Trochanter Ring Attachment Plates, ... 3.5 mm VA-Locking PPFx Distal Femur Spanning Attachment Plates, LEFT, SSt Holes Length 02.221.151 4 holes 142 mm 02.221.153 4 holes LONG 152 mm 02.221.155S* 6 holes 182 mmSYNTHES (USA) SYNTHES (Canada) Ltd. ... Date: Hospital: Surgeon: Procedure: Implants Patient Information: J12012B 3/13 Inventory Control Form 2.7 mm/3.5 mm Variable …Dec 6, 2008 · Device Name: Synthes 2.7 mm/3.5 mm LCP Distal Fibula Plates Indications for Use: The Synthes 2.7 mm/3.5 mm LCP Distal Fibula Plates are indicated for fractures, osteotomies, and non-unions of the metaphyseal and diaphyseal region of the distal fibula, especially in osteopenic bone. Prescription Use X AND/OR Over-The-Counter UseThe LCP Distal Fibula Plates are part of the Synthes locking compression plate system that merges locking screw technology with conventional plating techniques. The plates are available in stainless steel and titanium.An Ankle Fusion Plating module is included to address ankle fusion management. 7 plates families and 7 screw types are offered in the system, designed to treat both low and high energy fractures of the ankle. The all-in-one tray provides a solution for simple to complex injuries of the distal tibia and fibula.

All Depuy Synthes catalogs and technical brochures. ZERO-P NATURAL™PLATE. 5 Pages. 2.0 mm LCP® Distal Ulna Plate. 20 Pages. SYNFLATE SYSTEM. ... LCP Distal Fibula Plates. 32 Pages. LCP Distal Tibia Plate - Low Bend. 24 Pages. Variable Angle LCP Forefoot/Midfoot System 2.4/2.7. 40 Pages. TomoFix.Case Information: Synthes USA, LLC Synthes (Canada) Ltd. To order: (800) 523-0322 To order: (800) 668-1119. INVENTORY CONTROL FORM 3.5 mm LCP Distal Tibia T-Plate Implants (cont’d) Instruments 4.0 mm Cancellous Bone Screws, fully threaded LENGTH LENGTH 206.010 10 mm 206.012 12 mm1. DePuy Synthes 2.7mm VA LCP Clavicle Plates Surgical Technique Guide, 103752541 rev 2 01/21. 2. DePuy Synthes. Shape Verification Analyses. Windchill #0000290902, 0000295170, 0000290186, 0000290903, 2020. 3. Robinson CM. Fractures of the clavicle in the adult. Epidemiology and classification. J Bone Joint Surg Br. 1998;80:476-484. 4. palmettostatearmory coupon We would like to show you a description here but the site won't allow us. cta bus tracker 126 The Expert Tibial Nail permits an intra medullary approach for the fixation of proximal, shaft and distal fractures of the tibia. The system consists of a series of cannulated nails, can-nulated end caps, dual core locking screws and standard locking screws. All of the implants are made of titanium alloy (TAN*). ed weinstock age The FibuLock fibular nail is a cutting-edge, biologically friendly treatment for ankle fractures. It is inserted into the fibula through a small incision and acts like an internal splint to stabilize the fracture during healing. This minimally invasive technique may reduce wound complications often associated with standard open reduction internal fixation (ORIF) plating techniques.1 The ...LCP Distal Lateral Tibial Locking Plate - titanium alloy. Article: 1227.1*** Holes: 5-13 Length: 101-229 mm. learn more. LCP Distal Fibula/Tibia Plate - titanium alloy. Article: 1228.1*** Holes: 3-11 Length: 73-177 mm. learn more. LCP Medial Distal Tibia Plate - titanium alloy ... Bauer's Synthes. Estetic web design . To get a consultation ... the beekeeper showtimes near regal salisbury and rpx The LCP Low Bend Medial Distal Tibia Plate 3.5 mm is part of the Synthes Small Fragment LCP system that merges locking screw technology with conventional plating techniques. The combi-holes in the LCP plate shaft combine a dynamic compression unit (DCU) hole with a locking screw hole. Combi-holes provide the flexibility of axial compression and ... ff14 msq list Opening the Distal Femur 1 Position Patient Position the patient supine on a radiolucent table. The knee of the injured leg should be fl exed 30° – 40°. A leg roll may be used to allow proper reduction and stabiliza-tion of the fracture. Position the image intensifi er to allow visualization of the proximal and distal femur in AP and ...Distal Humerus Plates Synthes (USA) Synthes (Canada) Ltd. To Order: (800) 523-0322 To Order: (800) 668-1119 Date: Hospital: Surgeon: Procedure: Patient Information: Inventory Control Form 2.7 mm / 3.5 mm Variable Angle LCP Elbow System 02.107.002 2 holes, right 02.107.102 2 holes, left 2.7 mm / 3.5 mm Variable Angle LCP Proximal Olecranon Plates museum camp dog osrs Locking Distal Fibula Plates, Right QTY PRODUCT # HOLES PRICE LOT# UDI AR-9943BR-04 4 AR-9943BR-05 5 AR-9943BR-06 6 ... Inventory Control Form Author: Arthrex, Inc. virginia riverside mychart DePuy Synthes Stainless Steel Right LCP Lateral Distal Fibula Plate, 2.7/3.5 mm Size, 73 mm Length, 3 Holes DEPUY SYNTHES: 02.112.136 The store will not work correctly in the case when cookies are disabled.Inventory Control Form 3.5 mm Low Profile Pelvic System Some devices in this form may not have been licensed in accordance with Canadian law and may not be for sale Canada. Please contact your sales consultant items approved for sale in 3.5LPPELVICICF001v2 08/22 3.5 mm Cortex Screws, self-tapping, with T15 StarDrive Recess Length 02.200.010Titanium Cannulated Tibial Nail Surgical Technique DePuy Synthes 1 INTRODUCTION SURGICAL TECHNIQUE PRODUCT INFORMATION TABLE OF CONTENTS Titanium Cannulated Tibial Nail Expert Nailing System 2 ... until the distal tip is at the level of the physeal scar or the desired nail insertion depth. Mark the skin at that site. Move the C-arm to the ... old fashioned refusal crossword clue Predicate Device: Synthes 2.7 mm/3.5 mm LCP Distal Fibula Plates Synthes One Third Tubular LCP Plate Device Description: Synthes 2.7 mm/3.5 mm LCP Distal Fibula Plates are contoured to match the anatomy of the distal fibula and diaphyseal region. The plates feature a low-profile design and Combi holes (DynamicOpening the Distal Femur 1 Position Patient Position the patient supine on a radiolucent table. The knee of the injured leg should be fl exed 30° – 40°. A leg roll may be used to allow proper reduction and stabiliza-tion of the fracture. Position the image intensifi er to allow visualization of the proximal and distal femur in AP and ... ocala mugshots search The Hindfoot Arthrodesis Nail permits a proper hindfoot alignment due to features such as: · Distal and talar locking options. · A spiral blade. · Lateral bend · End caps for improved stability2,3. Get in Touch with a Sales Consultant. wildfire scooter parts (K04191 1) Synthes LCP Distal Femur Plates (K062564) to introduce modified instruments, which arc manual accessory ... ulna, humerus, tibia, fibula, and femur. The Synthes ALPS is also indicated for use with manual accessory instruments intended to be used with the Brainlab Trauma Navigation System Synthes LCP System is intended for buttressing ...The Acumed Fibula Nail 2 is designed to address simple, transverse, and short oblique fractures as well as osteotomies of the fibula. The Fibula Nail 2 includes: 12 nails offered in three diameters and four lengths including a small 2.6 mm diameter. 5° bend in the nail designed to accommodate the shape of the intramedullary canal. is dr shannon klingman married Jun 3, 2013 · Fig 7 VA-LCP Lateral Distal Fibula Plate with six 2.7 mm VA holes in the head in Stainless Steel VA-LCP Lateral Distal Fibula Plate in Titanium The Variable Angle LCP Ankle Trauma system also comprises a compression and distraction system, which is an important tool for reduction (i.e. bringing a fibula out to length) or compression of a ...14 Synthes Large and Medium-Size External Fixators Surgical technique Approach to the femur A lateral approach to the femur within a 30° angle is recom-mended. A medial approach is also possible from a distal direc-tion. Approach to the pelvis There are two recommended options for pin placement of the external fixation assembly in the pelvis.